NDT High Temperature Ultrasonic Couplant
NDT High Temperature Ultrasonic Couplant
NDT High Temperature Ultrasonic Couplant by Echo Ultrasonics has been drawing on over 50 years of experience in developing and manufacturing ultrasonic couplant’ s, we are constantly expanding our couplant performance parameters to address unmet needs, improve operator safety and facilitate the ease of use of our products.
Since Echo was founded in 2012 we have developed:
- Z+ high acoustic impedance ambient temperature couplant
- VersaSonic® high-temperature couplant (-10 to 700°F) in medium and high viscosity
- EchoTherm™ Extreme with an operating range up to 1250°F (675°C) and an auto-ignition temperature above 1300°F
- EchoPure™, a water-free, water-soluble couplant, will not frost on parts nor freeze in extremely cold conditions (-60°F), ideal for hot welds up to 350°F
- UltraSoniX™, EchoTrack™, SoniX® formulations with no formaldehydes, glycol ether, nitrites and nitrates
- EchoMix® Single: single packet powder couplant
- AUT and Robotic Fluid Couplants with low cost, water solubility and broad operating ranges.
VersaSonic High Temperature Ultrasonic Couplant
VersaSonic has a broad operating range of -10 to 700°F (-23 to 371°C).
Instantaneous ultrasonic response (does not contain plastic powders which delay ultrasonic conduction).
VersaSonic® is the most versatile couplant, from high temperature to turbine rotors to extreme weather inspections. VersaSonic is a low-toxicity, biodegradable couplant that does NOT contain peanut oil.
Excellent corrosion inhibitor. Provides non-toxic, superior, long-term corrosion inhibition for steel and cast iron and is compatible with other metals and most plastics. VersaSonic may be left in place unless it will interfere with subsequent manufacturing operations such as painting or electroplating.
| Operating Range | -10 to 700°F (-23 to 371°C) |
| Viscosity | Gel and paste Medium viscosity High viscosity |
| Halogens and Sulfur | Less than 50 ppm |
Low environmental impact. Contains no perfluorocarbons, silicones, peanut or tree nut oils.
HiTempco+ High Temperature Ultrasonic Couplant
HiTempco+ High Temperature Ultrasonic Couplant was Introduced in the mid-1970s by Aerotech/Krautkramer Branson, HiTempco has been the standard of performance in silicone-based high-temperature couplants for decades.
With a broad temperature range of -50˚ to 775˚F (-45˚ to 412˚C), its applications range from high-temperature thickness gaging and flaw detection to ambient and low-temperature coupling where no corrosion, broad material compatibility, long service life and low toxicity are considerations.
| Operating Range | -50˚ to 775˚F (-45˚ to 412˚C) |
| Viscosity | ≈40,000 cps. Brookfield |
| Flash Point | Cleveland Open Cup 649˚F (343˚C) |
| Auto-ignition | 820˚F (437˚C) |
Compliance: ASME Boiler & Pressure Vessel Code (T-533), ASTM F519, FAA AC #25-29 (Glycerin-free), NAVSHIPS 250-1500, Nuclear grade (less than 50 ppm Halogens & Sulfur), P91 Steel Inspection (Water-free)
(Does not contain plastic powders, which delay ultrasonic conduction and result in difficult-to-remove residues). Excellent corrosion inhibitor. Provides non-toxic, long-term corrosion inhibition for steel and cast iron and is compatible with other metals and most plastics. HiTempco may be left in place unless it will interfere with subsequent manufacturing operations such as painting or electroplating.
EchoTherm High Tempature Couplant
EchoTherm High Temperature Couplant contains a polymer that melts (and begins to smoke) at 750°F (400°C), extending the operating range. However, it is NOT necessary to reach this temperature to obtain instant readings.
A high-temperature thickness gauging and corrosion testing couplant that has an operating range of 200°F to 1000°F (93 to 538°C ) and an auto-ignition temperature of above 1300°F (704°C).
EchoTherm does not contain Teflon and is not expected to cause “polymer plume fever.”
If you are testing below 700°F, VersaSonic is the ideal broad temperature couplant with an operating range of -10 to 700°F.
| Operating Range | 200°F to 1000°F (93°C to 538°C) |
| Auto Ignition Temperature* | Greater than 1300°F (704°C). * Test by John A. Kennedy & Assoc., ASTM E659-14 |
| Flash Point | 1050°F (570°C) |
| Viscosity | Thick paste |
EchoTherm Extrem High Temperature Ultrasonic Couplant
EchoTherm Extrem High Temperature Ultrasonic Couplant is the first and only high-temperature ultrasonic couplant has an auto-ignition temperature and flash point above 1300ºF.
With no minimum operating range, no residue, less smoke and no auto-ignition under 1300ºF, EchoTherm Extreme is an ideal couplant for port inspections
EchoTherm Extreme is a high viscosity paste that adheres well to the transducer.
There is no low temperature operating limit with EchoTherm Extreme™, and the product performs like a high-performance ultrasonic couplant from below -40°F/C to above 1250°F (675°C).
| Operating Range | -40 to 1250°F+ (-40 to 675°C) |
| Auto Ignition Temperature | greater than 1300ºF * Test by John A. Kennedy & Assoc., ASTM E659-14 |
| Viscosity | Thick paste |
AeroSonix Drone UT Couplant
- Ideal couplant for drones
- Broad temperature range
- Optimal viscosity
- Pumps like a fluid, stays in place like a gel
- Non-toxic
- Environmentally benign
- High auto-ignition point
- Very low evaporation rate
- Will not form gums, varnish or impede small pumps and tubing
| Operating Range |
-50˚ to 775˚F (-45˚ to 412˚C) |
|---|---|
| Viscosity |
≈ 55,000 cps. |
| Brookfield Flash Point | Cleveland Open Cup 649˚F (343˚C) |
| Auto-ignition | 820˚F (437˚C) |
| Packaging |
2-fluid oz / 59 ml (volume) metal tube4-fluid oz / 118 ml (volume) metal tubeQuart / .95 liter, collapsible cubitainer, bottle, dispensing tap |
| Instantaneous ultrasonic response | (does not contain plastic powders which delay ultrasonic conduction and result in difficult-to-remove residues). Excellent corrosion inhibitor. |